3-7. INLET AIR HOUSING.
Removal.
(See figure
location.)
1-2 for
(1) Ensure that MASTER SWITCH is
in OFF position.
WARNING
To prevent injury, ensure that
battery is
disconnected before
performing maintenance on elec-
trical components.
(2) Disconnect battery cable plug
connector from battery.
(3) Remove power cable and cable
support assembly (paragraph 3-2).
(4) Remove
inlet
air
housing
access door (paragraph 4-16d, TM 5-
6115-612-12).
(5) Remove battery cable assembly
(paragraph 4-26a, TM5-6115-612-12).
(6) Remove
slave
receptacle
(paragraph 4-29b, TM 5-6115-612-12).
(7)
4-81a, TM
(8)
housing
Remove power cable (paragraph
5-6115-612-12).
Remove
air
filter muffler
(12) Open control panel access
door.
(13) Loosen
turnlock
fasteners
and remove EECM access cover.
(14) Loosen
turnlock
fasteners
and open control panel.
(15) Carefully pull wiring out of
inlet air housing into control fender.
(16) Close
control
panel
and
control panel access
(17) Remove 20
(paragraph 4-33b, TM
(18) Refer to
procedure to remove
door.
amp current shunt
5-6115-612-12).
paragraph 2-4a for
lockbolts. Remove
lockbolts that connect inlet air hous-
ing to generator set.
b. Repair.
(1) Weld cracks and holes.
(2) Remove dents.
(3) Remove corrosion and chipped
paint.
Prime and
repaint
affected
areas.
(4) Measure
and
fabricate
new
TM5-6115-612-12).
(paragraph
4-21a,
panels.
(9) Remove air baffle (paragraph
4-22a, TM 5-6115-612-12).
(10) Remove air filter (paragraph
3-9a).
(11) Remove
component
mounting
panel
(paragraph 4-82a, TM 5-6115-
612-12).
Carefully pull wiring through
access holes out of inlet air housing.
Refer to FO-1, TM 5-6115-612-12.
c.
Installation.
(1) Refer to paragraph 2-4a for
procedure to install lockbolts.
Place
inlet air housing in position and se-
cure with lockbolts.
(2) Open
control
panel
access
door.
(3) Loosen turnlock fasteners and
open control panel.
3-6