TM 55-2840-254-23
1-89
CHECK FOR STATIC OIL LEAKAGE (Continued)
1-89
7. After one hour, if there is more than 15 seconds
between drops, go to step 9. If there is less than
15 seconds between drops, proceed as follows:
a. Install packing (6) in groove (7) on chip detec-
tor (5).
b. Install chip detector (5) in housing (8).
Torque to 95 inch pounds. Use crowfoot
attachment. Lockwire chip detector (5) to bolt
(9). Use lockwire (E29).
c. Replace output shaft support housing
(Ref. Tasks 2-58 and 2-63).
8. If output shaft support housing is replaced, repeat
steps 6. and 7..
9. Install packing (6) in groove (7) on chip detector
(5).