1-89 CHECK FOR STATIC OIL LEAKAGE (Continued)
1-89
3. Let end of hose assembly (3) hang below
engine as shown and into container. Allow
to drain for one hour. If, after one hour,
one drop of oil falls every fifteen seconds
or less, replace oil pump check valve (Ref.
Tasks 8-4.1 and 8-4.2).
4. Connect hose assembly (3) to connector
(4).
GO TO NEXT PAGE
1-302
Change 5