TM 55-2840-254-23
1-89
CHECK FOR STATIC OIL LEAKAGE
References:
INITIAL SETUP
TM 55-2840-254-23P
Applicable Configurations:
Task 2-63
Task 2-58
All
Genera/ Safety Instructions:
Tools:
Powerplant Mechanic's Tool Kit.
Lubricating oils (E32 and E33) cause
Technical Inspection Tool Kit,
paralysis if swallowed. Prolonged con-
Crowfoot Attachment, 718-Inch
tact with them may irritate the skin.
Torque Wrench, 30-150 Inch-Pounds
Handle only in well-ventilated areas
Container. 1 Quart
away from heat and flame. Drain and
Stopwatch
store in approved metal safety contain-
Materials:
ers. Avoid prolonged or repeated con-
Lockwire (E29)
tact with skin and do not take internally.
Wiping Rag
Wash contacted area of skin thoroughly
Parts:
after handling. If Irritation of skin re-
Packing
sults, get medical attention. Get medical
Personnel Required:
attention for eyes.
GO TO NEXT PAGE
Pages 1-301 and 1-302 deleted
Change 10