5-13 INSTALL APU WIRING HARNESS ASSEMBLY (CONT)
8.
Connect electrical connectors (8, 9)
to hourmeter assembly.
9.
Slide sleeving (D33) down and center
over electrical connectors (8, 9).
9.1.
Install textile braid (D39A) two
places on each sleeve covering
connectors (8, 9).
9.2.
Each textile braid (D39A) must be
0.20 to 0.30 inch from ends of
sleeve.
Tie in a square knot.
9.3.
Apply coating (D6A) to knot and
10.
11.
12.
13.
14.
ends of textile braid (D39A).
Connect electrical connector (10)
(P6) to motional pickup transducer.
Lockwire electrical connector with
lockwire (D44).
Install clamp (11) and secure with
bolt (12) and nut (13). Torque
bolt to 25 to 29 inch-pounds.
Connect electrical connector (14)
(P7) to ignition unit receptacle.
Lockwire electrical connector with
lockwire (D44).
Install electrical connector (15)
(J289) on meter bracket.
Secure electrical connector (15) to
meter bracket with washers (16),
screws (17) and nuts (18). Torque
screws to 6 to 8 inch-pounds.