TM 55-2835-209-23
5-13 INSTALL APU WIRING HARNESS ASSEMBLY (CONT)
1.
2.
3.
4.
5.
6.
7.
NOTE
Remove protective caps from
APU wiring harness assembly
prior to attaching connectors.
Prior to assembly, all compo-
nents will be visually in-
spected for damage.
Position APU wiring harness assembly
on APU.
Install top bolt and tighten bottom
bolt securing inboard half of fire-
wall sleeves.
Connect electrical connector (1)
(P8) to low oil pressure switch re-
ceptacle.
Lockwire electrical con-
nector with lockwire (D44).
Connect electrical connector (2)
(P3) to fuel control wiring harness
receptacle.
Lockwire electrical
connector with lockwire (D44).
Connect electrical connector (3)
(P5) oil temperature bulb recepta-
cle.
Lockwire electrical connector
with lockwire (D44).
Install
Torque
Install
Torque
clamp (4) and bolt (5).
bolt to 33 to 37 inch-pounds.
clamp (6) and bolt (7).
bolt to 33 to 37 inch-pounds.
5-26