TM 1-2840-252-23-3
8-41
CLEAN DUAL CHIP DETECTOR
8-41
INITIAL SETUP
Equipment Condition:
Applicable Configurations:
Off Engine Task
All
Dual Chip Detector Removed (Task 8-39)
Dual Chip Detector Disassembled (Task 8-40)
Tools:
General Safety Instructions:
WARNING
Goggles
Dry cleaning solvent (E19) is flammable and
Dry, Compressed Air Source
toxic. It can irritate skin and cause burns.
Materials:
Use only in well-ventilated area, away from
Dry Cleaning Solvent (E19)
heat and open flame. In case of contact,
Gloves (E24)
immediately flush skin or eyes with water for
Lint-Free Cloth (E30)
at least 15 minutes. Get medical attention
Personnel Required:
for eyes.
1. Wear gloves (E24). Clean housing (1) and two filters (2). Use dry cleaning solvent (E19) and brush.
WARNING
When using compressed air for cleaning, use approved protective equipment for eyes and face. Do not
use more than 30 psig air pressure. Do not direct air toward yourself or another person. Failure to
comply could result in injury to eyes or skin. In case of injury, get medical attention.
2. Wear goggles. Blow dry housing (1) and filters (2), using clean, dry, compressed air.
3. Clean two connectors (3) with lint-free cloth (E30) dampened in dry cleaning solvent (E19)
FOLLOW-ON MAINTENANCE:
Inspect Dual Chip Detector (Task 8-42).
END OF TASK
8-96