TM 1-2840-252-23-3
3-40
DISASSEMBLE DUAL CHIP DETECTOR
8-40
INITIAL SETUP
General Safety Instructions:
Applicable Configurations:
WARNING
All
Lubricating oils cause paralysis if
Tools:
swallowed. Prolonged contact with them
may irritate the skin. Handle only in well-
ventilated areas away from heat and flame.
Vise
Drain and store in approved metal safety
Jaw Caps
containers. Avoid prolonged or repeated
Materials:
contact with skin and do not take internally.
Wiping Rag (E64)
Wash contacted area of skin thoroughly
Personnel Required:
after handling. If irritation of skin results,
get medical attention. Get medical attention
Equipment Condition:
for eyes.
Off Engine Task
Dual Chip Detector Removed (Task 8-39)
References:
Task 1-80
1. Remove lockwire, two magnetic chip detectors (1) and packings (2). Use vise with jaw caps.
When removing filter from connector, be careful not to push in or deform screen of filter. Pushed in or
deformed screen are cause for rejection.
NOTE
The following step applies to both magnetic chip detectors.
2. Unscrew and remove filter (3) from connector (4).
GO TO NEXT PAGE