TM 55-2840-254-23
7-20.1
7-20.1 TEST MAIN ELECTRICAL CABLE ASSEMBLY (SIX CONNECTOR) (Continued)
i. Touch red probe (2) to electrical connector
(3), pin B (8).
j. Touch black probe (5) to electrical connector
(6), pin V (9).
k. Meter shall indicate zero ohms.
l. Set multimeter range switch to R x 1.
m. Touch red probe (2) to electrical connector
(10), center pin (11).
n. Touch black probe (5) to electrical connector
(6), pin A (12).
o. Meter shall indicate zero ohms.
q. Touch black probe (5) to all other pins on
electrical connector (6).
r. Meter shall indicate 1000 ohms minimum.
GO TO NEXT PAGE