TM 55-2840-254-23
7-20.1 TEST MAIN ELECTRICAL CABLE ASSEMBLY (SIX CONNECTOR) (Continued)
7-20.1
bo. Touch red probe (2) to electrical connector
(20), pin F (31).
bp. Touch black probe (5) to electrical
connector (6), pin b (32).
bq. Meter shall indicate zero ohms.
br.
bs. Touch black probe (5) to all other pins on
electrical connector (6).
Meter shall indicate 1000 ohms minimum.
bt.
bu. Set multlmeter range switch to R x 1.
bv. Touch red probe (2) to electrical connector
(33), pin A (34).
bw. Touch black probe (5) to electrical
connector (6), pin K (35).
bx. Meter shall indicate zero ohms.
by.
Set multlmeter range switch to R x 1000.
bz. Touch black probe (5) to all other pins on
electrical connector (6).
ca. Meter shall indicate 1000 ohms minimum.
GO TO NEXT PAGE
7-126.6
Change 1