TM 55-2840-254-23
7-20.1 TEST MAIN ELECTRICAL CABLE ASSEMBLY (SIX CONNECTOR) (Continued)
7-20.1
am. Set multimeter range switch to R x 1.
an. Touch red probe (2) to electrical connector
(20), pin B (23).
ao. Touch black probe (5) to electrical
connector (6), pin X (24).
ap. Meter shall indicate zero ohms.
Touch black probe (5) to all other pins on
a r.
electrical connector (6).
Meter shall indicate 1000 ohms minimum.
as.
at.
Set multimeter range switch to R x 1.
au. Touch red probe (2) to electrical connector
(20), pin C (25).
av. Touch black probe (5) to electrical
connector (6), pin Y (26).
aw. Meter shall indicate zero ohms.
ax.
ay.
Touch black probe (5) to all other pins on
electrical connector (6).
Meter shall indicate 1000 ohms minimum.
az.
GO TO NEXT PAGE
7-126.4
Change 1