TM 55-2840-254-23
7-20
7-20 TEST MAIN ELECTRICAL CABLE ASSEMBLY (NINE CONNECTOR) (Continued)
cb. Touch red probe (2) to electrical connector
(33), pin B (36).
cc. Touch black probe (5) to electrical
connector (6), pin C (37).
cd. Meter shall indicate zero ohms.
cf. Touch red probe (2) to electrical connector
(3B), pin A (39).
cg. Touch black probe (5) to electrical
connector (6), pin G (40).
ch. Meter shall indicate zero ohms.
ci.
Touch black probe (5) to all other pins on
cj.
electrical connector (6).
ck. Meter shall indicate 1000 ohms minimum.
GO TO NEXT PAGE