7-20 TEST MAIN ELECTRICAL CABLE ASSEMBLY (NINE CONNECTOR) (Continued)
7-20
cl.
Set multimeter range switch to R x 1.
cm. Touch red probe (2) to electrical connector
(38), pin B (41).
cn. Touch black probe (5) to electrical
connector (6), pin H (42).
co. Meter shall indicate zero ohms.
cq. Touch black probe (5) to all other pins on
electrical connector (6).
Meter shall indicate 1000 ohms minimum.
cr.
Set multimeter range switch to R x 1
cs.
Touch red probe (2) to electrical connector
ct.
(38), shell (43).
cu. Touch black probe (5) to electrical
connector (6), pin J (44).
Meter shall indicate zero ohms.
cv.
cx. Touch black probe (5) to all other pins on
electrical connector (6).
Meter shall indicate 1000 ohms minimum.
cy.
NOTE
It is not necessary to test three remaining
GO TO NEXT PA GE
7-124
Change 1