TM 55-2835-209-23
7-10 INSTALL POWER SECTION ASSEMBLY (AVIM) (CONT)
8.
Torque bolts (7, 9) to 47 to 53
inch-pounds per torque pattern.
9.
Reposition APU in maintenance stand
to horizorital position.
10.
Remove nuts (11, 12) from immersion
thermocouple connections.
11.
Install marked leads (1O). Install
nuts (11, 12) on studs.
Torque
nuts to 38 to 42 inch-pounds. In-
stall ground wire on upper side of
immersion thermocouple and secure
using bolt (12.1) and nut (13).
Torque bolt to 38 to 42 inch-
pounds.
12.
Install clamp (14) on immersion
thermocouple lead.
Secure to
bracket with bolt (15) and nut
(16).
Torque bolt to 38 to 42
inch-pounds.
7-22