TM 55-2835-209-23
7-9 TOUCH UP GEARBOX ASSEMBLY HOUSING ANODIZE (AVIM) (CONT)
1.
2.
3.
4.
5.
6.
Position gearbox housing on work
surface.
NOTE
This task is for damaged area
less than 5 percent of surface
area or shorter than 1/2 inch
in length.
Clean damaged area with
1,1,1-trichloroethane (D41) and cot-
ton applicator (D10).
Dry part thoroughly with clean, fil-
tered compressed air.
Cotton applicator, saturated
with iridite solution, consti-
tutes a fire hazard if allowed
to dry.
Immediately after
use, rinse thoroughly in tap
water.
Apply iridite solution (D15) to dam-
aged area with cotton applicator
(D10). Keep surface wet 1 minute.
Rinse treated area with tap water 80
to 110°F (26.6 to 43.3°C).
Dry part thoroughly with clean, fil-
tered compressed air.
FOLLOW-ON MAINTENANCE: None.
Change 1
7-19