TM 55-2835-209-23
4-8 TOUCH UP ANODIZE FUEL CONTROL LOWER COVER (AVIM) (CONT)
NOTE
This task is for damaged area
less than 5 percent of surface
area or shorter than 1/2 inch
in length.
1. Clean damaged area with 1,1,1-
trichloroethane (D41) and cotton ap-
plicator (D10).
2. Drv part thoroughly with clean, fil-
tered compressed air.
constitutes a fire hazard if
allowed to dry.
Immediately
after use, rinse thoroughly in
tap water.
3. Apply iridite solution (D15) to dam-
aged area with cotton applicator
(D1O). Keep surface wet 1 minute.
4.
Rinse treated area with tap water 80
to llO°F (26.6 to 43.3°C).
5. Ory part thoroughly with clean, fil-
tered compressed air.
FOLLOW-ON MAINTENANCE: None.
4-23