T M 5 5 - 2 8 3 5 - 2 0 9 - 23
Section VII REPLACE FUEL CONTROL LOWER COVER NUT PLATES
4-7 REPLACE FUEL CONTROL LOWER COVER NUT PLATES (AVIM)
T h i s t a s k c o v e r s : a . R e m o v a l b . I n s t a l l a t i o n
INITIAL SETUP
T o o l s:
A i r c r a f t I n s p e c t i o n T o o l K i t ( T 4 9 )
E n g i n e R e p a i r m a n s T o o l K i t ( T 4 7)
P e r s o n n e l R e q u i r e d:
6 8 B A i r c r a f t P o w e r p l a n t I n s p e c t or
6 8 B A i r c r a f t P o w e r p l a n t R e p a i r er
68G Airframe Repairman
M a t e r i a l s / P a r t s :
Acid Swabbing Brush (D5)
E p o x y P r i m e r ( D 3 0 )
M a c h i n e r y T o w e l ( D 2 0)
R i v e t
1 , 1 , 1 - T r i c h l o r o e t h a n e ( D 4 1)
R e f e r e n c e s:
T M
5 5 - 1 5 0 0 - 2 0 4 - 2 5 /1
Equipment Conditions:
Fuel Control Lower Cover Removed
From APU
G e n e r a l S a f e t y I n s t r u c t i o n s :
1,1,1-Trichloroethane
is
toxic
t o s k i n , e y e s a n d r e s p i r a t o r y
t r a c t .
Skin and eye pro-
t e c t i o n a r e r e q u i r e d .
A v o id
r e p e a t e d o r p r o l o n g e d c o n t a c t .
W o r k i n a w e l l - v e n t i l a t ed
a r e a .
Epoxy pri
t o x i c t o
p i r a t o r y
personnel
mer is flammable and
e y e s , s k i n a n d r e s-
t r a c t .
T o p r e v e nt
i n j u r y , s k i n a n d e ye
p r o t e c t i o n a r e r e q u i r e d .
A v o i d p r o l o n g e d o r r e p e a t ed
c o n t a c t .
G o o d g e n e r a l v e n t i -
l a t i o n i s n o r m a l l y a d e q u a t e.
P o w e r t o o l o p e r a t i o n s c r e a te
a i r b o r n e p a r t i c l e s .
Eye pro-
tection is required. Remove
j e w e l r y p r i o r t o u s e . A d e -
q u a t e v e n t i l a t i o n o r r e s p i r a -
t o r i s r e q u i r e d .
4 - 2 0
Change 1