TM 5-6115-590-12
System No. I (lower
Part number ............................................. 185618-100
for recharge only ..............................197 cc (approx)
Type ......................................................... Single stage,
(.42 pt)
axial flow
System No. 2 (upper.........................
Rating ....................................................... 5500 cfm at 2.15
for recharge only ..............................180 cc (approx)
in. of H20
(.38 pt)
static pressure
Refrigeration compressors:...............
Rpm ......................................................... 3800
(2 used).............................................
Volts ......................................................... 120/208
Manufacturer ....................................AiResearch Manu-
Frequency ................................................ 400 Hz
facturing Com-
Phase ....................................................... 3
pany of Los
Amps ........................................................ 15
Angeles
Watts ....................................................... 3750
Part number .....................................572030-1-2
ERDL ....................................................... 13217E4072
Type .................................................Two stage
centrifugal
Recirculating fan:
Rpm .................................................23,300
(4 used)
Duty Cycle ........................................Continuous
Manufacturer ............................................ AiResearch Menu-
Volts .................................................120/208
facturing Com-
Frequency ........................................400
Hs ............................................................. pany of Los
Phase ...............................................3
Angeles
Amps ................................................60
Part number ............................................. 605370-1-2
Type ......................................................... Single stage
axial flow
Refrigerant receivers:
(2 used)
Rating........................................................ 1620 cfm st 3.45
Manufacturer.....................................AiResarch Manu-
in of H20
facturing Com-
static pressure
pany of Los
Rpm .......................................................... 5700
-Angeles
Volts ......................................................... 120/208
Frequency ................................................ 400 Hz
Part number ......................................184270-1-1
Phase........................................................ 3
Refrigerant receivers:
Amps......................................................... 6.0
Refrigerant receivers:
(2 used)
Recirculating fan (alternate):
Manufacturer ....................................AiResearch Manu-
(4 used)
facturing Com-
Manufacturer ............................................ Sunstrand Avia-
pany of Los
tion, Div. of
Angeles
Sunstrand Corp.
Part number .....................................184260-1-1
Rockford, Ill
Type .................................................Aluminum plate
Part number .............................................. 185617-100
fin
Refrigerant evaporators:
Type.......................................................... Single stage,
(2 used)
axial flow
Manufacturer.....................................AiResearch Manu-
Rating ....................................................... 1620 cfm at 3.45
facturing Corn-
in. of H20
pany of Los
static pressure
Angeles
Rpm .......................................................... 5750
..........................................................
Volts ......................................................... 120/208
Part number .....................................184250-1-1
Frequency................................................. 400 Hz
Type .................................................Aluminum plate
Phase ....................................................... 3
fin
Amps ........................................................ 6.0
Condenser cooling fan:
Watts ....................................................... 1600
(4 used).............................................
ERLD ........................................................ 13217E4071
Manufacturer ....................................AiResearch Manu-
(7) Water system
..........................................................facturing Co-
Pump, motor driven,
pany of Los
(cold water)
Angeles
Manufacturer ............................................ Skurka Engineer-
Part number .....................................605890-3-1
ing Co.
Type..................................................Single stage
Part number .............................................. A675-CD659
axial flow
Volts ......................................................... 208
Rating ...............................................5500 cm at 2.15
Amps ........................................................ 2.2
-in. of H2O
HP............................................................. 0.5
static pressure
Phase........................................................ 3
Rpm ..................................................3800
Frequency................................................. 400 Hz
Volts..................................................120/208
Rpm .......................................................... 11,000
Frequency.........................................400 Hz
Flow .......................................................... 12 gpm
Amps.................................................15
Hot water pressure at
Condenser cooling fan (alternate).....outlet connection
10 psig
(4 used) ............................................
Hot water flow (with no
Manufacturer.....................................Sunstrand Avia-
cold water flowing) ....................................6 gpm
tion, Div. Of
Cold water pressure at
Sunstrand Corp.
outlet connection....................................... 10 psig
Rockford, Ill
Cold water flow (with no
hot water flowing)......................................9 gpm
1-32