TM 5-6115-590-12
Emergency lighting
Refrigeration compressor
power requirements ..........................10.0 amps
power requirement, each
Fuel boost pump (alternate):
(2 in system)
19.5 .......................................................... kw
Manufacturer ....................................Stanadyne
(nominal)
Part number .....................................20633
Condenser cooling fan
Discharge pressure ..........................15.0 plig (max)
power requirement, each
Current requirements........................3.25 amps
(4 in system) ............................................ 4.9 kw
Volts .................................................24V
Recirculating fan power
ERDL ...............................................13217E4034
requirement, each
(4)
60 Hz electrical system .....................(4 in system)
1.95 kw
Rating ...............................................120/240V AC, 60
Water pump power
Hz single phase,
requirement, each
3-wire
(2 in system) ............................................ 0.23 kw
Neutral conductor .............................Ungrounded
Generator:
Internal 60 Hz power
Manufacturer ........................................... Bendix Corp.,
requirements ....................................None
Red Bank Div.
Power available for............................Part number
28B94-15-A
external requirements .......................12.5 kva, 10kw at
Style ......................................................... A
0.80 pf
PMG voltage ............................................ 29 +1
Generator:
Type.......................................................... Three phase, 4
Manufacturer ....................................Bendix Corp.,
wire
Red Bank Div.
P/F ........................................................... 0.80
Part number .....................................5188-3-A
KVA .......................................................... 120
PMG (permanent ..............................
KW .......................................................... 96
magnet generator).............................
Frequency ................................................ 400 Hz
voltage ..............................................23 ± IV
Volts.......................................................... 120/208
Type .................................................Single phase,
Amps (100% load) ................................... 333
3 wire
Rated rpm ................................................ 6000
P/F (power factor) ............................0.80
Weight ...................................................... 133 lb.
KVA ..................................................12.5
(60.38 Kg)
KW ...................................................10.0
Frequency.........................................60 Hz
Volts .................................................120/ 240V
Voltage regulator:
Amps (100% load) ............................53
Manufacturer ........................................... Bendix Corp.,
Rated rpm ........................................3,60Red Bank Div.
Weight .............................................118 lb.
Part number ............................................. 20B100-2
(53.37 Kg)
Style ......................................................... A
Type .................................................Solid State
Voltage regulator:
Volts ......................................................... 120/208
Manufacturer ....................................Bendix Corp.,
Frequency................................................. 400 Hz
Red Bank Div.
Phase ...................................................... 3
Part number .....................................20B123-1
Adjustable range ...................................... 115 to 125 volts
Style .................................................B
line to neutral
Type .................................................Solid State
Sensing..................................................... Average 3 phase
Volts .................................................120/240
(6) Conditioned air system
Frequency ........................................60 Hz
Heating capacity (at sea
Phase ...............................................1
level and ambient
Adjustable range ..............................115 to 125 volts
temperature-25-F (-4°C)) ......................... 350,000 btu/hr
line to neutral
Cooling capacity, each
Sensing ............................................Average phase
system (two systems used) ..................... 10 tons (approx)
with high phase
(120,000 btu/hr
limiting on
with 460 cfm
overvoltage.
make-up air at
Average phase
120°F (49°C))
with low phase
Refrigerant specification .......................... R114 (Federal
control on
Specification
undervoltage.
BB-F-671)
(5)
400 Hz electrical system...................Refrigerant capacity:
Rating ...............................................120/208V AC, 400
System No. 1 (lower) ............................... 39 lb. (approx)
Hz three phase,
(17.7 Kg)
4-wire
System No. 2 (upper) ............................... 36 lb. (approx)
Neutral conductor .............................Grounded
(16.3 Kg)
Output:
Refrigerant operating
Total .................................................120 kva, 96 kw at
pressure.................................................... 70
to 90 psig
0.80 P/F ............................................Refrigerant maximum
External with air
pressure ................................................... 135 +7 psig
conditioning or
Refrigeration oil capacity-
heating .............................................30 kw
System No. I (lower) ................................ 590 cc (approx)
External with no air
(1.24 pt)
conditioning or
System No. 2 (upper) ............................... 540 cc (approx)
heating .............................................90 kw
(1.14 pt)
Change 6
1-31