TM 5-6115-590-12
(2)
Cleaning and Inspection.
(a)
Clean
relay
with
filtered
compressed air or wipe with a clean rag moistened with
an approved cleaning solvent.
(b)
Visually inspect relay for corrosion,
cracks, damaged threads or other evidence of damage.
(3)
Installation. Install replacement relay in
reverse order of removal
f.
Relay (K33).
(1)
Removal. Tag and disconnect electrical
connectors from relay. Remove four screws and eight
washers from relay Remove relay.
(2)
Cleaning and Inspection.
(a)
Clean
relay
with
filtered
compressed air or wipe with a clean rag moistened with
an approved cleaning solvent
(b)
Visually inspect relay for corrosion,
cracks, damaged threads or other evidence of damage.
(3)
Installation. Install replacement relay in
reverse order of removal.
g.
Relay (K34).
(1)
Removal. Remove terminal post cover
from relay. Tag and disconnect electrical connections
from relay. Remove four screws and eight washers
from relay. Remove relay.
(2)
Cleaning and Inspection. Clean relay with
filtered compressed air or wipe with a clean rag
moistened with an approved cleaning solvent.
(3)
Installation. Install replacement relay in
reverse order of removal procedures.
h.
Current Transformer (two used: CT4 and CT5).
(1)
Removal. Tag and disconnect electrical
connections to transformer. Tag and disconnect
electrical connection passing through the center of
transformer. Remove four screws and eight washers
from transformer. Remove transformer.
(2)
Cleaning and Inspection.
(a)
Clean
transformer
with
filtered
compressed air or wipe with a clean rag moistened with
an approved cleaning solvent.
(b)
Visually
inspect
for
corrosion,
cracks, damaged threads or other evidence of damage.
(3)
Installation. Install in reverse order of
removal procedures.
4-60. Generator, 400 Hz
a.
General. Maintenance of the 400 Hz generator
at organizational level consists only of inspection. If the
generator fails the inspection, notify direct support
maintenance.
b.
Inspection. Remove generator terminal cover
and inspect terminals and wiring for corrosion, loose
connections and terminals. Inspect wiring for damaged
insulation and burned wires. Inspect electrical
harness connector for loose or bent pins and damaged
threads Replace damaged parts.
c.
DELETED.
4-61. Generator, 60 Hz
a.
General. Maintenance of the 60 Hz generator at
organizational level consists only of inspection. If the
generator fails the inspection, notify direct support
maintenance.
b.
Inspection. Remove generator terminal cover
and inspect terminals and wiring for corrosion, loose
connections and terminals. Inspect wiring for damaged
insulation and burned wires. Inspect electrical harness
connector for loose or bent pins and damaged threads.
Replace damaged parts.
c.
DELETED.
4-62. Lines and Hoses
a.
Removal. Remove lines and hoses only as
required. Tag or otherwise identify connection points,
routing, orientation of fittings and location of supporting
clamps for aid at reassembly.
b.
Cleaning and Inspection .
(1)
Clean lines and hoses with an approved
cleaning solution.
(2)
Visually inspect lines and hoses for
cracks, corrosion, damaged threads and other obvious
damage. Replace all damaged parts.
e.
Installation. Install lines and fittings in reverse
order of removal
Change 7 4-94