TM 55-2840-254-23
6-26
6-26 CLEAN START FUEL NOZZLES
INITIAL SETUP
Equipment Condition:
Off Engine Task
Applicable Configurations:
All
General Safety Instructions:
Tools:
Goggles
Compressed Air Source
Dry cleaning solvent (E17) is flammable
and toxic. It can irritate skin and cause
Materials:
burns. Use only in well-ventilated area,
Dry Cleaning Solvent (E17)
away from heat and open flame. In case
Gloves (E20)
of contact, immediately flush skin or
Lint-Free Cloth (E26)
eyes with water for at least 15 minutes.
Get medical attention for eyes.
Personnel Required:
1. Wear gloves (E20). Clean start fuel nozzles (1).
Use dry cleaning solvent (E17) and brush.
2. After cleaning, remove residue with clean lint-
free cloth (E26).
When using compressed air for cleaning,
use approved protective equipment for
eyes and face. Do not use more than 30
psig air pressure. Do not direct air to-
ward yourself or another person. Fail-
ure to comply could result in injury to
eyes or skin. In case of injury, get medi-
cal attention.
3. Wear goggles. Blow out internal air passage (2).
To clean stuck ball, use clean, dry compressed
air.
FOLLOW-ON MAINTENANCE:
END OF TASK