TM 55-2840-254-23
1-86 INSPECT CONTAMINATED OIL SYSTEM (Continued)
1-86
NOTE
following procedure applies to both chip
When removing filter from connector, be
careful not to push in or deform screen
of filter. Pushed in or deformed screen
is cause for rejection.
b. Unscrew and remove filter (14) from connec-
tor (15).
Dry cleaning solvent (E17) is flammable
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
away from heat and open flame. In case
of contact, immediately flush skin or
eyes with water for at least 15 minutes.
Get medical attention for eyes.
c. Wear gloves (E20). Clean filter (14). Use dry
cleaning solvent (E171 and brush.
When using compressed air for cleaning,
use approved protective equipment for
eyes and face. Do not use more than 30
psig air pressure. Do not direct air toward
yourself or another person. Failure to
comply could result in injury to eyes or
skin. In case of injury, get medical at-
tention.
d. Wear goggles. Dry filter (14) using clean, dry
compressed air.
e. Clean connector (15) with lint-free cloth (E26)
dampened in dry cleaning solvent (E17).