TM 55-2835-209-23
6-13 REPLACE LOW OIL PRESSURE SWITCH (CONT)
REMOVAL
To prevent clogging or contam-
ination, all exposed openings
in fuel, oil, air lines and
electrical connectors will be
capped immediately.
Be sure
caps and plugs are clean.
1.
Disconnect electrical connector (1).
2.
Remove low oil pressure switch (2).
Remove and discard packing (3).
3.
Clean low oil pressure switch (2)
using process 7, Chapter 8.
INSTALLATION
NOTE
As tubes and connectors are
installed and connected, pro-
tective caps and plugs shall
be removed.
Prior to assembly, components
will be visually inspected for
damage.
1.
Lubricate packing (3) with lubricat-
ing oil (D16) and install on low oil
pressure switch (2).
2.
Install low oil pressure switch (2).
Torque to 61 to 68 inch-pounds.
3.
Connect electrical connector (1) to
low oil pressure switch (2). Lock-
wire connector with lockwire (D43).
4.
Lockwire low oil pressure switch (2)
with lockwire (D43).
FOLLOW-ON MAINTENANCE: None.
6-21