TM 55-2835-209-23
6-11 REPLACE OIL TEMPERATURE BULB (CONT)
REMOVAL
1.
Drain oil from APU (Task 6-2).
2.
Remove electrical connector (1) from
oil temperature bulb (2). Remove
oil temperature bulb (2).
3.
Remove packing (3) and discard.
4.
Clean oil temperature bulb (2) using
process 7, Chapter 8.
INSTALLATION
NOTE
Prior to assembly, all compo-
nents will be inspected for
damage.
1.
Lubricate packing (3) with lubricat-
ing oil (D16).
Install packing on
oil temperature bulb (2).
2.
Install oil temperature bulb (2).
Torque to 57 to 63 inch-pounds.
Lockwire with lockwire (D44).
3.
Connect electrical connector (1) to
oil temperature bulb (2). Lockwire
with lockwire (D43).
Service lubrication system (Task
4.
6-19).
FOLLOW-ON MAINTENANCE: None.
Change 1
6-17