TM 55-2835-209-23
6-14 TOUCH UP OIL FILTER ELEMENT COVER ANODIZE (AVIM) (CONT)
NOTE
This task is for damaged area
less than 5 percent of surface
area or shorter than 1/2 inch
in length.
1.
Clean damaged area with 1,1,1-
trichloroethane (D41) and cotton ap-
plicator (D10).
2.
Dry thoroughly with clean, filtered
compressed air.
Cotton applicator, saturated
with iridite solution, consti-
tutes a fire hazard if allowed
to dry.
Immediately after
use, rinse thoroughly in tap
water.
3.
Apply iridite solution (D15) to dam-
aged area with a cotton applicator,
keep surface wet 1 minute.
4.
Rinse treated area with tap water 80
to 110°F (27 to 43°C).
5.
Dry part thoroughly with clean, fil-
tered compressed air.
FOLLOW-ON MAINTENANCE: None.
6-23