TM 55-2835-209-23
5-6 REPLACE METER BRACKET NUT PLATES (AVIM) (CONT)
REMOVAL
1. Drill out rivets (1) retaining nut
plate (2).
2. Punch out ri
rivet stems
vet stems.
Discard
and nut plate.
INSTALLATION
NOTE
Prior to assembly. all compo-
1.
2.
3.
4.
nents will be visually in-
spected for damage.
Clean all surfaces of parts to be
assembled with 1,1,1-trichloroethane
(D41) and machinery towel (D20).
Using acid brush (D5). apply a wet
coat of epoxy primer (D30) to meter
bracket and rivet (1). Allow to dry
for 3 minutes.
Insert rivet (1) through meter
bracket and nut plate, install rivet
to retain nut plate.
Coat both ends of rivet (1) with
epoxy primer (D30).
Allow to dry.
FOLLOW-ON MAINTENANCE: None.
5-14