TM 55-2835-209-23
5-2 REPLACE IMMERSION THERMOCOUPLE (CONT)
INSTALLATION
1.
2.
3.
4.
5.
6.
7.
NOTE
Prior to assembly, components
will be visually inspected for
damage.
Install gasket (1) on immersion
thermocouple (2).
Install immersion thermocouple (2)
with (CR) facing forward and install
in combustor case.
Apply antiseize compound (D7) to
threads of bolt (3).
Install ground wire on upper side of
immersion thermocouple and secure
immersion thermocouple using bolts
(3), stud (4, deleted) and nuts (5).
Torque bolts to 38 to 42
inch-pounds.
Remove nuts (7, 8) from immersion
thermocouple connections and install
marked leads (6).
Install nuts (7, 8), nut (9, de-
leted) on studs.
Torque nuts to 38
to 42 inch- pounds.
Secure fastener studs securing rear
panel to firewall.
FOLLOW-ON MAINTENANCE: None.
5-6