TM 55-2835-209-23
Section III TOUCH UP ANODIZE FUEL CONTROL UPPER COVER
4-3 TOUCH UP ANODIZE FUEL CONTROL UPPER COVER (AVIM)
INITIAL SETUP
Tools:
tract.
Skin and eye pro-
Air Blow Gun
tection are required.
Avoid
Air Hose
repeated or prolonged contact.
Rubber Gloves
Work in a well-ventilated
Safety Glasses
area.
Personnel Required:
Compressed air is dangerous
68B Aircraft Powerplant Repairer
when directed toward yourself
or another person.
The air-
Materials/Parts:
Cotton Applicator (D1O)
stream or material blown by
the airstream can cause inju-
I r i d i t e
( D 1 5 )
ry, particularly to the eyes
1,1,1-Trichloroethane (D41)
and face.
Use goggles to pro-
tect eves and face.
Do not
Equipment Conditions:
exceed 30 PSI. Do not direct
Fuel Control Cover Remove From
airstream toward yourself or
APU (Task 4-1)
another person.
General Safety Instructions:
Iridite solution is toxic to
skin, eyes and respiratory
tract.
Skin and eye pro-
tection are required.
Avoid
repeated or prolonged contact.
1,1,1-Trichloroethane is toxic
Work in a well-ventilated
area.
to skin, eyes and respiratory
4-6
Change 1