TM 55-2835-209-23Section III TOUCH UP ANODIZE FUEL CONTROL UPPER COVER4-3 TOUCH UP ANODIZE FUEL CONTROL UPPER COVER (AVIM)INITIALSETUPTools:tract.Skin and eye pro-Air Blow Guntection are required.AvoidAir Hoserepeated or prolonged contact.Rubber GlovesWork in a well-ventilatedSafety Glassesarea.PersonnelRequired:Compressed air is dangerous68B Aircraft Powerplant Repairerwhen directed toward yourselfor another person.The air-Materials/Parts:Cotton Applicator (D1O)stream or material blown bythe airstream can cause inju-I r i d i t e ( D 1 5 ) ry, particularly to the eyes1,1,1-Trichloroethane (D41)and face.Use goggles to pro-tect eves and face.Do notEquipmentConditions:exceed 30 PSI. Do not directFuel Control Cover Remove Fromairstream toward yourself orAPU (Task 4-1)another person.GeneralSafetyInstructions:Iridite solution is toxic toskin, eyes and respiratorytract.Skin and eye pro-tection are required.Avoidrepeated or prolonged contact.1,1,1-Trichloroethane is toxicWork in a well-ventilatedarea.to skin, eyes and respiratory4-6Change 1