TM 55-2835-208-23
2-73 CLEAN AND INSPECT IGNITION EXCITER
2-73
INITIAL SETUP
Applicable Configurations:
Materials:
Lint-Free Cloth (E13)
None
All
Personnel Required:
Tools:
68B Aircraft Powerplant Repairer
68B Powerplant Inspector
Equipment Condition:
Off APU Task
Do not use cleaning solvent to
clean exciter. Use of solvent can
result in failure of the exciter.
1. Wipe external surfaces of ignition exciter
(1) with clean dry cloth (E13).
2.
Inspect ignition exciter for dents, cracks
and crossed or stripped connection
threads (2). If damaged discard.
NOTE
Slight bulging of the exciter is ac-
ceptable provided exciter func-
tions properly.
3. Inspect nutplates (3) for security and
crossed threads. If damaged, repair,
(Task 2-72).
4. Check plugs (2) for damaged or bent
pins. Repair or replace as required.
FOLLOW-ON MAINTENANCE:
None
END OF TASK
Change 4
2-139