TM 55-2835-208-23
2-75 REMOVE IGNITION CABLE
2-75
INITIAL SETUP
Applicable Configurations:
All
Tools:
Engine Repairmans Tool Kit
NSN 5180-00-323-4944
Materials:
None
Personnel Required:
68B Aircraft Powerplant Repairer
Equipment Condition:
APU in Assembly Fixture (Task 1-22)
1.
2.
3.
Do not disconnect ignition cable
within 30 minutes of running or
attempting to start APU. Volt-
ages used can cause arcing which
may result in severe burns. Use
extreme care when working with
ignition system.
Failure to ob-
serve all precautions may result in
serious injury or death.
lockwire
Remove
from connector (1).
Remove nut (3), bolt (4) and spacer (5)
to release clamps (6), (7) and (8).
Disconnect ignition cable (9) from igni-
tion exciter (10).
GO TO NEXT PAGE
2-142
Change 4