TM 55-2835-208-23
2-77 REMOVE IGNITER PLUG
2-77
INITIAL SETUP
Applicable Configurations:
All
Tools:
Engine Repairmans Tool Kit
NSN 5180-00-323-4944
Materials:
None
Personnel Required:
68B Aircraft Powerplant Repairer
Equipment Condition:
APU in Assembly Fixture (Task 1-22)
Do not disconnect ignition
cable within 30 minutes of
running or attempting to start
APU.
Voltages used can cause
arcing which may result in
severe burns. Use extreme
care when working with
ignition system. Failure to
observe all precautions may
result in serious injury or
death.
1.
Remove lockwire from ignition
cable (1).
Disconnect igni-
tion cable (1) from igniter
plug (2).
2. Remove igniter plug (2).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
Change 2
2-145