ARMY
TM 5-6115-612-34
MARINE CORPS
TM 6115-34/8
AIR FORCE
TO 35C2-3-471-2
NAVY
AG-320B0-MME-000
10-2. ENGINE
ELECTRONIC
MODULE (EECM). (cont.)
(h) Any discrepancy
CONTROL
noted during
above procedure indicates a failure in EECM
contractor enable circuit. Refer to Table 2-4,
Malfunction 9, step 2.
(11) Overspeed test.
(a) Adjust function generator to a
frequency between 0 and 200 Hz and adjust
millivolt source to .96 to 1.20 millivolts.
(b) Move MASTER SWITCH to
RUN position. All lights should be off.
NOTE
Read step (c) completely before per-
forming step (c).
(c) Move MASTER SWITCH to
START position.
The STARTER light should
come on.
Quickly increase function generator
frequency until READY TO LOAD light comes
on. This should happen between 3287 and 3421
Hz.
The FUEL light should be on and the
STARTER light should have gone off.
(d) Slowly increase function genera-
tor frequency until engine OVERSPEED light
comes on.
This should happen between 3615
and 3763 Hz. All other lights should be off.
(e)
OFF position.
off.
(f)
Move MASTER SWITCH to
OVERSPEED light should go to
Any discrepancy noted during
the above procedure indicates a failure in the
EECM overspeed circuit. Refer to Table 2-4,
Malfunction 5.
(12) Low oil test.
(a) Adjust function generator to a
frequency between 0 and 200 Hz and adjust
millivolt source to .96 to 1.20 millivolts.
10-14
Change 1
NOTE
EECM electronics requires a frequency
below 200 Hz.
(b) Move MASTER SWITCH to
RUN position. All lights should be off.
NOTE
Read step (c) completely before per-
forming step (c).
(c) Move MASTER SWITCH to
START position.
The STARTER light should
come on.
Quickly increase function generator
to a frequency between 2900 and 3200 Hz before
EECM timeout.
During frequency increase
IGNITION and FUEL lights will come on and then
STARTER and IGNITION lights will go off.
(This should happen between 1965 and 2059
Hz). The FUEL light should remain on.
(d) Continue to increase function
generator frequency slowly until READY TO
LOAD light comes on.
This should happen
between 3287 to 3421 Hz.
(e) Move LOW OIL switch to ON
position.
LOW OIL PRESSURE light should
come on. Start timing device. Stop timing device
when all other lights go off. This should happen
between 0.5 and 2.0 seconds.
(f) Move LOW OIL switch to OFF
position. The LOW OIL PRESSURE light should
stay on.
(g) Move MASTER SWITCH to
OFF position. All lights should be off.
(h) Any discrepancy noted during
the above procedure indicates a failure in the
EECM low oil pressure circuit. Refer to Table
2-4, Malfunction 7.
(13) Generator over temperature fault test.
(a) Adjust function generator to a
frequency between 0 and 200 Hz and adjust
millivolt source to .96 to 1.20 millivolts.