4-2. GENERATOR ELECTRONIC CONTROL
MODULE. (cent)
ARMY
TM 5-6115-612-34
MARINE CORPS
TM 6115-34/8
AIR FORCE
TO 35C2-3-471-2
AG-320BO-MME-OOO
Figure 4-1. GECM Test Setup
Table 4-1. GECM Test Equipment
NOMENCLATURE
MFR and MODEL
QTY
NSN
DIGITAL MULTIMETER
AN/PSM-45
1
6625-01-139-2512
(0-20 MegaOhm ± 1%
Simpson Model 467
(0-40 Vdc ± 1%)
or equivalent
DIGITAL MULTIMETER
AN/GSM-64D
1
6625-01-221-9367
(0-60 millivolts dc
Fluke Model 8840 A/AF
( ± 0.5 millivolts)
or equivalent
GECM Test Fixture
Fabricated
1
Part No. 101815
(CAGE 51225)
POWER SUPPLY NO.1
Kepco, Inc.
1
6130-01-143-5967
(0-30 Vdc ± 0.5 V 10 Amps)
Model ATE36-15M or equivalent
POWER SUPPLY NO.2
Equivalent
1
6130-00-000-0000
(0-40 Vdc ± 0.5 V
POWER SUPPLY NO.3
Equivalent
1
6130-00-000-0000
(0-5 Vdc ± 0.1 V
POWER SUPPLY NO.4
Use 10-turn potentiometer
1
6130-00-000-0000
(Millivolt Source
(30K ohm), with BA 3090/U
0-60 millivolts dc ± 0.5 millivolts)
Battery (9 Vdc) or equivalent
4 - 3