TM 55-2840-254-23
7-18.1 INSPECT
MAIN ELECTRICAL CABLE
ASSEMBLY (SIX CONNECTOR)
7-18.1
INITIAL SETUP
Materials:
None
Applicable Configurations:
All
Personnel Required:
Tools:
Technical Inspection Tool Kit,
Equipment Condition:
Off Engine Task
Inspect main electrical cable assembly (1).
There shall be no frayed or burned insulation.
There shall be no loose connections or broker
wires.
2. Inspect sleeving (2). There shall be no frayed
or broken sleeving.
GO TO NEXT PAGE