TM 55-2840-254-23
7-17.1
7-17.1 CLEAN MAIN ELECTRICAL CABLE ASSEMBLY (SIX CONNECTOR)
INITIAL SETUP
Equipment Condition:
Off Engine Task
Main Electrical Cable Assembly Removed
Applicable Configurations:
All
General Safety Instructions:
Tools:
Goggles
compressed Air Source
Methyl ethyl ketone (E36) is flamma-
ble and toxic. It can irritate skin
and cause burns. Use only in well-
Materials:
Gloves (E20)
ventilated area, away from heat and
Lint-Free Cloth (E26)
open flame. In case of contact, im-
Methyl Ethyl Ketone (E36)
mediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Personnel Required:
1. Wear gloves (E20). Clean main electrical
cable assembly (1). Use lint-free cloth (E26)
dampened with methyl ethyl ketone (E36).
Wipe dry using clean, dry, lint-free cloth (E26).
GO TO NEXT PAGE
Change 1