TM 55-2840-254-23
6-43 CLEAN
FLOW DIVIDER AND BRACKET
6-43
INITIAL SETUP
General Safety Requirements:
Applicable Configurations:
All
Tools:
Dry cleaning solvent (E17) is flam-
mable and toxic. It can irritate skin
and cause burns. Use only in well-
ventilated area, away from heat and
Materials:
open flame. In case of contact, im-
Dry Cleaning Solvent (E17)
mediately flush skin or eyes with
Gloves (E20)
water for at least 15 minutes. Get
Lint-Free Cloth (E26)
medical attention for eyes.
Personnel Required:
Equipment Condition:
Off Engine Task
1. Clean flow divider (1) as follows:
a. Wear gloves (E20). Clean flow divider using
dry cleaning solvent (E17) and brush.
b. Wipe dry. Use lint-free cloth (E26).
GO TO NEXT PAGE