TM 55-2840-254-23
6-10
6-10 CLEAN FUEL BOOST PUMP ASSEMBLY
INITIAL SETUP
General Safety Instructions:
Applicable Configurations:
All
Tools:
Dry cleaning solvent (E17) is flammable
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
Materials:
away from heat and open flame. In
Dry Cleaning Solvent (E17)
case of contact, immediately flush skin
Gloves (E20)
or eyes with water for at least 15 min-
Lint-Free Cloth (E26)
utes.. Get medical attention for eyes.
--
Personnel Required:
Equipment Condition:
Off Engine Task
Fuel Boost Pump Assembly Removed (Task
1. Wear gloves (E20). Clean fuel boost pump as-
sembly (1). Use dry cleaning solvent (E17) and
brush.
2. Remove any remaining solvent with clean, Iint-
free cloth (E26).
FOLLOW-ON
MAINTENANCE:
END OF TASK