TM 55-2840-254-23
Section Ill. FUEL BOOST PUMP ASSEMBLY MAINTENANCE PROCEDURES
6-9
6-9 REMOVE FUEL BOOST
PUMP ASSEMBLY
General Safety Instructions:
INITIAL SETUP
Applicable Configurations:
All
Tools:
Turbine fuels are very flammable. They
may cause drying and irritation of skin
Container, 1 Quart
or eyes. Handle only in well-ventilated
areas away from heat and open flame.
Drain and store in approved metal
Materials:
Wiping Rag(E58)
safety containers. Avoid prolonged or
repeated contact with skin and do not
take internally. Wash contacted area
Personal Required:
of skin thoroughly after handling. If
irritation of skin results, get medical
attention. Get medical attention for
eyes.
GO TO NEXT PAGE