TM 55-2840-254-23
1-96 SERVICE OIL FILLER STRAINER (Continued)
1-96
3. Clean oil filler strainer (3) as follows:
Dry cleaning solvent (E17) is flammable
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
away from heat and open flame. In case
of contact, immediately flush skin or
eyes with water for at least 15 minutes.
Get medical attention for eyes.
a. Wear gloves (E20). Immerse in dry cleaning
solvent (E17) and agitate. Use brush on
screen (5).
When using compressed air for cleaning,
use approved protective equipment for
eyes and face. Do not use more than
30 psig air pressure. Do not direct air
toward yourself or another person. Fail-
ure to comply could result in injury to
eyes or skin. In case of injury, get medi-
cal attention.
b. Wear goggles. Blow dry screen (5). Use clean,
dry compressed air.
4. Inspect oil filler strainer (3). There shall be no
broken wires (6).
GO TO NEXT PAGE
1-377