1-95
1-95 SERVICE STARTER GEARBOX FILTER (Continued)
1. Remove lockwire, starter gearbox filter (1),
washer (2) and packing (3).
2. Clean starter gearbox filter (1) as follows:
Dry cleaning solvent (E17) is flammable
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
away from heat and open flame. In case
of contact, immediately flush skin or
eyes with water for at least 15 minutes.
Get medical attention for eyes.
a. Wear gloves (E20). Immerse filter in dry clean-
ing solvent (E17) and agitate. Use brush on
threads (4).
When using compressed air for cleaning,
use approved protective equipment for
eyes and face. Do not use more than 30
psig air pressure. Do not direct air toward
yourself or another person. Failure to com-
ply could result in injury to eyes or skin.
In case of injury, get medical attention.
b. Wear goggles. Blow dry starter gearbox filter
(1) and internal passage (5). Use clean, dry
compressed air.
GO TO NEXT PAGE
1-372