1-96 SERVICE OIL FILLER STRAINER
1-96
INITIAL SETUP
References:
TM 55-2840-254-23P
Applicable Configurations:
All
General Safety Instructions:
Tools:
Powerplant Mechanic's Tool Kit,
Technical Inspection Tool Kit,
Lubricating oils (E32 and E33) cause
paralysis if swallowed. Prolonged con-
Goggles
tact with them may irritate the skin.
Compressed Air Source
Handle only in well-ventilated areas
away from heat and flame. Drain and
Materials:
store in approved metal safety con-
Dry Cleaning Solvent (E17)
tainers. Avoid prolonged or repeated
Gloves (E20)
contact with skin and do not take in-
Lockwire (E29)
ternally. Wash contacted areas of skin
Wiping Rag (E58)
thoroughly after handling. If irritation
of skin results, get medical attention.
Parts:
Get medical attention for eyes.
Packing
Personnel Required:
GO TO NEXT PAGE
1-375