1-86 INSPECT CONTAMINATED OIL SYSTEM
INITIAL SETUP
General Safety Instructions:
Applicable Configurations:
All
Tools:
Powerplant Mechanic's Tool Kit,
Lubricating oils (E32 and E33) cause
paralysis if swallowed. Prolonged con-
Technical Inspection Tool Kit,
tact with them may irritate the skin.
Handle only in well-ventilated areas
Oil Sample Bottle
away from heat and flame. Drain and
Approved Metal Safety Container
store in approved metal safety con-
Compressed Air Source
tainers. Avoid prolonged or repeated
Goggles
contact with skin and do not take in-
Utility Pail
ternally. Wash contacted areas of skin
thoroughly after handling. If irrita-
tion of skin results, get medical atten-
Materials:
Dry Cleaning Solvent (E17)
tion. Get medical attention for eyes.
Gloves (E20)
Lint-Free Cloth (E26)
Lockwire (E29)
Wiping Rag (E58)
Dry cleaning solvent (E17) is flammable
Parts:
Packings
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
away from heat and open flame. In case
Personnel Required:
of contact, immediately flush skin or
eyes with water for at least 15 minutes.
Get medical attention for eyes.
References
TM 55-2840-254-23P
Task 5-19
Task 8-19
Task 5-20
Task 8-2
Task 8-25
Task 8-3
Task 8-73
Task 8-18
Task 8-74
Task 8-81
Task 8-77
Task 8-82
Task 8-78
GO TO NEXT PAGE