T M 5 5 - 2 8 3 5 - 2 0 9 - 2 3
3-15 INSPECT HOT SECTION COMPONENTS (AVIM) (CONT)
1.
2.
3.
4.
5.
6.
7.
Inspect combustion chamber (Task
3-3).
Inspect combustor case (Task 3-7).
4-11).
NOTE
Inspect compressor airflow de-
flector as follows.
Visually inspect surfaces for nicks,
dents or cracks.
No damage allowed.
If cracks are suspected, fluorescent
penetrant per MIL-STD-6866.
Visually inspect anti-rotation
notches (reference A) for wear. No
wear allowed.
Visually inspect for deformation.
No deformation allowed.
NOTE
Inspect airflow deflector as
follows.
Visually inspect surfaces for defor-
mation or cracks.
No deformation or
cracks allowed.
If cracks are sus-
pected, fluorescent penetrant per
MIL-STD-6866.
Visually inspect anti-rotation
notches (reference A) for wear. No
wear allowed.
A
1-464-174
A
1-664-170
3-38