TM 55-2835-209-23
3-9 REPLACE COMBUSTOR CASE NUT PLATES (AVIM) (CONT)
REMOVAL
1.
Position combustor case on work sur-
face to gain access to nut plates.
2.
Remove rivets (1) (Task 3-9) from
nut plate (2).
Discard nut plate.
INSTALLATION
1.
Clean mating surfaces using 1,1,1-
trichloroethane (D41) and machinery
towel (D20).
2.
Using acid brush (D5), apply a wet
coat of epoxy primer (D30) to grip
area of rivet and bore area.
Air
dry a minimum of 3 minutes.
3.
Position nut plate (2) on bracket
(3) and secure in place using riv-
ets.
4.
Cover rivet ends with epoxy primer
(D30).
FOLLOW-ON MAINTENANCE: None.
3-20