TM 55-2835-209-23
3-1 REMOVE COMBUSTOR CASE (AVIM) (CONT)
Exercise care when disconnect-
ing igniter plug lead to pre-
vent damage to igniter plug
lead tips.
To prevent clogging or contam-
ination,
all exposed openings
in fuel, oil, air lines and
electrical connectors will be
capped or plugged immediately.
Be sure caps and plugs are
clean.
1.
Disconnect igniter plug lead (1)
from igniter plug assembly (2).
2.
Remove igniter plug assembly (2) and
washer (3) from combustor case.
3.
Remove nut (4), bolt
(6).
4.
Remove nut (7) and
NOTE
(5) and clamps
bracket (8).
To aid in assembly, leads
should be marked prior to re-
moval.
5.
Remove nuts (9, 10). nut (11, de-
leted) from immersion thermocouple
(16).
Remove leads (12) from stud
marked (AL) and stud marked (CR).
Install nuts (9, 10) back on immer-
sion thermocouple.
6.
Remove nuts (13), bolts (14), stud
(15, deleted) and ground wire.
7.
Remove immersion thermocouple (16).
8.
Remove gasket (17) from immersion
thermocouple and discard.
3-2