TM 55-2835-209-23
6-7 TOUCH UP LUBE PUMP COVER ANODIZE (AVIM) (CONT)
NOTE
This task is for damaged area
less than 5 percent of surface
area or shorter than 1/2 inch
in length.
1. Clean damaged area with 1,1,1-
trichloroethane (D41) and cotton ap-
plicator (D1O).
2. Dry thoroughly with clean, filtered
compressed air.
Cotton applicator, saturated
with iridite solution, con-
stitutes a fire hazard if al-
lowed to dry. Immediately
after use, rinse thoroughly
in tap water.
3. Apply iridite solution (D15) to dam-
aged area with a cotton applicator
(D10), keep surface wet 1 minute.
4.
Rinse treated area with tap water 80
to 11O°F (27 to 43°C).
5. Dry part thoroughly with clean, fil-
tered compressed air.
FOLLOW-ON MAINTENANCE: None.
6-9