TM 55-2835-209-23
Section Vll TOUCH UP LUBE PUMP COVER ANODIZE
6-7 TOUCH UP LUBE PUMP COVER ANODIZE (AVIM)
INITIAL SETUP
Tools:
Air Gun
Air Hose Assembly
Rubber Gloves
Safety Glasses
Personnel Required:
68B Aircraft Powerplant Repairer
Materials/Parts:
Cotton Applicator (D1O)
Iridite (D15)
1,1,1-Trichloroethane (D41)
Equipment Conditions:
Lube Pump Cover Removed From APU
General Safety Instructions:
1,1,1-Trichloroethane is toxic
to skin, eyes and respiratory
tract.
Skin and eye pro-
tection are required. Avoid
repeated or prolonged contact.
Work in a well-ventilated
area.
Compressed air is dangerous
when directed toward yourself
or another person.
The air-
stream or material blown by
the airstream can cause inju-
ry, particularly to the eyes
and face.
Use goggles to pro-
tect eyes and face.
Do not
exceed 30 PSI. Do not direct
airstream toward yourself or
another person.
Iridite solution is toxic to
skin, eyes and respiratory
tract.
Skin, and eye pro-
tection are required. Avoid
repeated or prolonged contact.
Work in a well-ventilated
area.
6-8
Change 1