TM 55-2835-208-23
2-68 CLEAN AND INSPECT BASE ASSEMBLY
2-68
INITIAL SETUP
Materials Required:
Applicable Configurations:
Dry-Cleaning Solvent (E20)
Lint-Free Cloth (E13)
All
Personnel Required:
Tools:
68B Aircraft Powerplant Repairer
Engine Repairmans Tool Kit
68B Powerplant Inspector
NSN 5180-00-323-4944
Rubber Gloves
Equipment Condition:
NSN 8415-00-266-8677
Container
Off APU Task
Eye Protection
Dry-cleaning solvent (E20)
is flammable and toxic.
It can irritate skin and
cause burns.
Use only in
well-ventilated area, away
from heat and open flame.
Wear gloves and eye pro-
tection.
In case of
contact,
immediately flush
eyes or skin with water for
at least 15 minutes. Get
medical attention for eyes.
1. Wearing gloves, wipe base (1)
with clean cloth (E13) dampened
with
dry-cleaning
solvent
(E20).
2.
Dry base (1) with clean dry
cloth (E13).
3.
Inspect base (1) for dents,
cracks or
deformed
flange
(2).
Repair if damaged (Task
2-69).
4.
Inspect for broken receptacles
(3).
Replace if damaged (Task
2-69).
GO TO NEXT PAGE
2-130