TM 55-2835-208-23
2-25 CLEAN AND INSPECT START FUEL NOZZLE HOLDER ASSEMBLY
2-25
INITIAL SETUP
M a t e r i a l s:
Applicable Configurations:
Methyl-Ethyl Ketone (MEK) (E9)
Lint-Free Cloth (E13)
A ll
Tools:
Personnel Required:
Rubber Gloves
68B Aircraft Powerplant Repairer
NSN 8415-00-266-8677
68B Powerplant Inspector
Container
Eye Protection
Equipment Condition:
Off APU Task
MEK (E9) is flammable and
t o x i c.
I t c a n i r r i t a t e
skin and cause burns.
Use only in well-ventilated
area, away from heat and
open flame.
Wear gloves
a n d e y e p r o t e c t i o n . In
case of contact, immediately
flush skin or eyes with
water for at least 1 5
minutes.
G e t
m e d i c a l
a t t e n t i o n f o r e y e s .
1.
Soak in MEK (E9) for 5 minutes.
2.
Remove from MEK and dry with
c l e a n l i n t - f r e e c l o t h ( E 1 3 ) .
3.
I n s p e c t f i t t i n g ( 1 ) a n d n o z z l e
( 2 ) f o r c a r b o n d e p o s i t s o r
c l o g g i n g i n o r i f i c e s .
4.
There
s h a ll
be
no
carbon
d e p o s i t s o r c l o g g i n g.
I f s o ,
repeat steps 1 and 2.
GO TO NEXT PAGE
2-52