3-1.
GENERAL.
Consumable
operating
and
maintenance supplies required to perform maintenance
or operate the generator set are listed In
Table 3-1. Items listed are identified by assigned
National Stock Numbers (NSN)
Table 3-1. Consumable Operating and Maintenance Supplies
Component
National
Description
Qty. required
Qty. Required
Notes
Application
Stock
for initial
8 hours
Number
operation
operation
Engine
9150-00-
Lubricant
4 quarts
For temperatures
270-4057
MIL-L-7808
(3 785 liters)
-65° F (-53.9° C)
to 125° F (51 7° C)
9150-00-
MIL-L-23699
4 quarts
For temperatures
985-7099
(3 785 liters)
-40° F (-40° C) to
400° F (204.4° C)
Fuel System
9130-00-
FUEL
32 gallons
64 gallons
256-8613
MIL-T-5624
(121.1 liters)
(242 3 liters)
JP-4/JP-5
6810-00-
Ethyl Alcohol O-E-760
General Cleaning
782-2686
6850-00-
Solvent PD-680,
General Cleaning
331-3350
Type III
Banned From
Trichloroethylene
General Cleaning
Use
O-T-634
Tnchloroethylene
Vapor Degreasing
1. 1. 1
MIL-T-81533
Battery
6810-00-
Electrolyte
Battery Fluid
249-9354
Distilled Water
Battery Service
8040-00-
Adhesive, Locking
General Repair
826-3535
MIL-A-46050
Power Cable
This Is no longer
used.
Spark Igniter
8030-00-
Anti-seize Compound
059-2761
MIL-A-907E FSC
8030 (MO11-2836)
Change 7 3-1